Description

Overview

SMC ITV2060 belongs to the SMC ITV1000/2000/3000 series of closed-loop electro-pneumatic regulators for stepless control of compressed air pressure in proportion to electrical input signals. Using dual air-supply and exhaust solenoid valves with internal pressure-sensor feedback, the ITV2000 body size handles up to 1.0 MPa maximum supply pressure across 0.005 to 0.1 MPa, 0.005 to 0.5 MPa, or 0.005 to 0.9 MPa set pressure ranges, including 10-bit parallel digital input (60 / ITV2060 configurations), analog current/voltage, preset, and industrial fieldbus protocols.

SMC ITV2060 ITV2000 series electro-pneumatic regulator with digital pressure display

Features

  • Closed-loop proportional control: Sensitivity within 0.2% F.S., hysteresis within 0.5% F.S., repeatability within ±0.5% F.S., and standard linearity within ±1% F.S. (with ±0.5% F.S. available via -X410).
  • Wide command signal compatibility: Supports 4 to 20 mADC, 0 to 20 mADC, 0 to 5 VDC, 0 to 10 VDC, 4-point or 16-point preset inputs, 10-bit parallel digital input, RS-232C, CC-Link, DeviceNet, PROFIBUS DP, and IO-Link.
  • Built-in digital pressure display: Indicates outlet pressure in MPa (min. unit 0.001), kgf/cm² (0.01), bar (0.01), psi (0.1), or kPa (1) with ±2% F.S. ±1 digit accuracy.
  • Monitor output options: Provides 1 to 5 VDC analog output, 4 to 20 mADC sink output, or NPN/PNP open-collector switch output.
  • IP65 environmental enclosure: Protected against dust and low-pressure water jets when exhaust and breathing ports are piped per catalog precautions.
  • Multi-station manifold capability: ITV1000 and ITV2000 models support 2 through 8-station manifold mounting (-X26).

Technical Data

Standard specifications for the SMC ITV1000/2000/3000 series:

ParameterITV101□ / ITV201□ / ITV301□ITV103□ / ITV203□ / ITV303□ITV105□ / ITV205□ / ITV305□
FluidAirAirAir
Set pressure range0.005 to 0.1 MPa0.005 to 0.5 MPa0.005 to 0.9 MPa
Min. supply pressureSet pressure + 0.1 MPaSet pressure + 0.1 MPaSet pressure + 0.1 MPa
Max. supply pressure0.2 MPa1.0 MPa1.0 MPa
Proof pressure (Supply / Output)0.3 MPa / 0.2 MPa1.5 MPa / 1.0 MPa1.5 MPa / 1.0 MPa
Power supply voltage24 VDC ±10% or 12 to 15 VDC24 VDC ±10% or 12 to 15 VDC24 VDC ±10% or 12 to 15 VDC
Current consumption0.12 A or less (24 VDC); 0.18 A or less (12 to 15 VDC)0.12 A or less (24 VDC); 0.18 A or less (12 to 15 VDC)0.12 A or less (24 VDC); 0.18 A or less (12 to 15 VDC)
Input signal options4–20 mADC, 0–20 mADC, 0–5 VDC, 0–10 VDC, 4/16-pt preset, 10-bit digital, Fieldbus4–20 mADC, 0–20 mADC, 0–5 VDC, 0–10 VDC, 4/16-pt preset, 10-bit digital, Fieldbus4–20 mADC, 0–20 mADC, 0–5 VDC, 0–10 VDC, 4/16-pt preset, 10-bit digital, Fieldbus
Input impedanceCurrent: 250 Ω or less; Voltage: Approx. 6.5 kΩ; Digital: Approx. 4.7 kΩCurrent: 250 Ω or less; Voltage: Approx. 6.5 kΩ; Digital: Approx. 4.7 kΩCurrent: 250 Ω or less; Voltage: Approx. 6.5 kΩ; Digital: Approx. 4.7 kΩ
Monitor outputAnalog 1–5 VDC / 4–20 mADC (±6% F.S.), or NPN (Max. 30 V, 80 mA) / PNP (Max. 80 mA)Analog 1–5 VDC / 4–20 mADC (±6% F.S.), or NPN (Max. 30 V, 80 mA) / PNP (Max. 80 mA)Analog 1–5 VDC / 4–20 mADC (±6% F.S.), or NPN (Max. 30 V, 80 mA) / PNP (Max. 80 mA)
Linearity / Hysteresis / Repeatability±1% F.S. / 0.5% F.S. / ±0.5% F.S. or less±1% F.S. / 0.5% F.S. / ±0.5% F.S. or less±1% F.S. / 0.5% F.S. / ±0.5% F.S. or less
Sensitivity / Temp. characteristics0.2% F.S. / ±0.12% F.S./°C or less0.2% F.S. / ±0.12% F.S./°C or less0.2% F.S. / ±0.12% F.S./°C or less
Ambient & fluid temperature0 to 50°C (No condensation)0 to 50°C (No condensation)0 to 50°C (No condensation)
EnclosureIP65IP65IP65
Weight (without options)ITV10□□: Approx. 250 g; ITV20□□: Approx. 350 g; ITV30□□: Approx. 645 gITV10□□: Approx. 250 g; ITV20□□: Approx. 350 g; ITV30□□: Approx. 645 gITV10□□: Approx. 250 g; ITV20□□: Approx. 350 g; ITV30□□: Approx. 645 g

Note: Add 50 g for 10-bit digital input models and 70 g for 16-point preset input models. Communication models (CC, DE, PR, RC, IL), 16-point preset input, and 10-bit digital input require 24 VDC power supply. Install a 5 μm or finer air filter upstream on the supply side.

Communication Specifications

ProtocolCC-Link (-CC)DeviceNet (-DE)PROFIBUS DP (-PR)RS-232C (-RC)IO-Link (-IL)
VersionVer. 1.10Volume 1 (Ed. 3.8) / Vol. 3 (Ed. 1.5)DP-V0—Ver. 1.1 (Class A)
Communication speed156 k / 625 k / 2.5 M / 5 M / 10 Mbps125 k / 250 k / 500 kbps9.6 k to 12 Mbps9.6 kbps230.4 kbps (COM3)
Configuration file—EDSGSD—IODD
I/O data occupation4 words / 4 words, 32 bits / 32 bits16 bits / 16 bits16 bits / 16 bits—4 bytes / 2 bytes
Data resolution12 bits (4096)12 bits (4096)12 bits (4096)10 bits (1024)12 bits (4096)
Current consumption0.16 A or less0.14 A or less0.16 A or less0.12 A or less0.12 A or less
Weight (ITV2000)430 g420 g450 g420 g420 g

Construction and Component Parts

SMC ITV2060 ITV2000 series internal sectional construction diagram

Main component parts for the ITV2000 series:

No.DescriptionMaterial
1BodyAluminum alloy
2Intermediate bodyAluminum alloy
3CoverAluminum alloy
4Valve guideAluminum alloy
5Valve (Supply valve)HNBR / Brass
6Valve (Exhaust valve)HNBR / Brass
7Valve springStainless steel
8Valve springStainless steel
9Diaphragm assemblyStainless steel, Aluminum alloy, HNBR, Steel
10SealNBR
11Bias springStainless steel
12O-ringNBR
13CotterStainless steel
14Wear ringResin
15SealNBR
16Bowl assemblyResin, Silicone rubber
17Sub-plateResin
18SealNBR
19Control circuit assembly—
20Solenoid valve—
21O-ringNBR
22O-ringNBR
23Cross recessed round head screwSteel

Dimensions and Accessories

SMC ITV2060 ITV2000 series external dimensional drawing with flat bracket

Accessory and bracket part numbers for the ITV1000/2000/3000 series:

  • Flat bracket assembly (ITV20□□ / ITV30□□): P398020-600 (weight 90 g, tightening torque 1.5 ±0.05 N·m; ITV1000 uses P398010-600 at 0.76 ±0.05 N·m).
  • L-bracket assembly (ITV20□□ / ITV30□□): P398020-601 (weight 90 g; ITV1000 uses P398010-601).
  • 4-core power/analog cable (3 m): P398020-500-3 (straight, 180 g) or P398020-501-3 (right angle, 180 g).
  • 13-core 10-bit digital input cable (3 m straight): INI-398-0-59 (310 g; right angle connector not available for 10-bit digital input).

Ordering Information

SMC ITV1000/2000/3000 part number breakdown (ITV [Model] 0 [Pressure] [Voltage] - [Input] [Monitor] [Thread] [Port] [Bracket] [Cable] [Unit] - [Made to Order]):

  • Model & Port: 1 (ITV1000: 1 = 1/8, 2 = 1/4), 2 (ITV2000: 2 = 1/4, 3 = 3/8), 3 (ITV3000: 2 = 1/4, 3 = 3/8, 4 = 1/2).
  • Pressure range: 1 (0.1 MPa), 3 (0.5 MPa), 5 (0.9 MPa).
  • Power supply: 0 (24 VDC), 1 (12 to 15 VDC).
  • Input / Communication: 0 (4–20 mADC), 1 (0–20 mADC), 2 (0–5 VDC), 3 (0–10 VDC), 40 (4-pt preset), 52 (16-pt preset NPN), 53 (16-pt preset PNP), 60 (10-bit digital input), CC (CC-Link), DE (DeviceNet), PR (PROFIBUS DP), RC (RS-232C), IL (IO-Link).
  • Monitor output: 1 (1–5 VDC), 2 (NPN switch), 3 (PNP switch), 4 (4–20 mADC), Nil (None).
  • Thread / Bracket / Cable / Display unit: Thread Nil (Rc), N (NPT), T (NPTF), F (G); Bracket Nil / B (Flat) / C (L); Cable S (3 m straight) / L (3 m right angle) / N (None); Display Nil (MPa), 2 (kgf/cm²), 3 (bar), 4 (psi), 5 (kPa).

Specify SMC ITV2060 or exact ITV ordering code, thread type, port size, input/monitor options, and quantity when requesting a quotation.